GAS sensor for Chlorine Gas

Kuntze Gas Sensors are amperometric sensors for the detection of chlorine gas.
The matching fitting Ne GSH allows for an easy installation of the gas sensor.

Benefits 

• Short response times
• High reliability
• Simple start-up due to printed calibration value

Applications
Ambient Air Monitoring
Warehouse Exhaust Air
Measuring Parameter
  •  0.. 20 ppm   

Ambient Conditions
  • Temperature -20.. +50 °C

  • Humidity 15.. 90% rH (non condensating)

  • Storage Life 6 months in container at +4.. 10 °C

  • Influence of Humidity No effect on the zero point

Version
Type/Configuration Description Article number

GAS sensor for Chlorine Dioxide

Kuntze Gas Sensors are amperometric sensors for the detection of chlorine dioxide gas. The matching fitting Ne GSH allows for an easy installation of the gas sensor.

Benefits 

  • Short response times

  • High reliability

  • Simple start-up due to printed calibration value

Applications
Ambient Air Monitoring
Warehouse Exhaust Air
Measuring Parameter
  • 0.. 5 ppm   

Ambient Conditions
  • Temperature:  -20.. +50 °C 

  • Humidity: 15.. 90% rH (non condensating)

  • Storage Life: 6 months in container at +4.. 10 °C

  • Influence of Humidity: No effect on the zero point

Versions
Type/Configuration Description Article number

GAS sensor for Ozone Gas

Kuntze Gas Sensors are amperometric sensors for the detection of ozone gas. The matching fitting Ne GSH allows for an easy installation of the gas sensor.

Benefits 

  • Short response times

  • High reliability

  • Simple start-up due to printed calibration value

Applications
Ambient Air Monitoring
Warehouse Exhaust Air
Measuring Parameter
  • 0.. 5 ppm   

Ambient Conditions
  • Temperature: -20.. +50 °C

  • Humidity: 15.. 90% rH (non condensating)

  • Storage Life: 6 months in container at +4.. 10 °C

  • Influence of Humidity: No effect on the zero point

Versions
Type/Configuration Description Article number