dialog W 2 CM R
dialog W 2 CM R
dialog W 2 CM R
Double conductivity measuring and control instrument
dialog W 2 CM R
- Easy and safe operation by plain text menu guidance
- Log book function
- Graphical trend display of the last 3 h
- Linear and non-linear special pure water temperature compensation
description
The dialog W 2 CM R is a sophisticated instrument for the precise measurement and control of the conductivity (double/ difference measurement). It is available in a wall mounted housing.applications
Cooling And Boiler Feed Water
Waste Water Treatment
Drinking Water / Beverages
Process Water
particular characteristics
- Variable assignment of relay and current outputs
- 2 limit values with delay
- Dosage check
- Serial interface RS 485
- 3 scaleable, galvanically isolated 0/4 .. 20 mA outputs
- 2 separate PID-controller
- Real time clock
- Background illuminated two-line graphical display
- Password function
information
Measuring and control instruments of the dialog series are also available for 117 VAC and 24 VDC (only wall mounted housing) - wihtout additional charge.technical data
measuring parameter |
|
| Conductivity (conductive) | 0 .. 200.0 µS/cm |
| 0 .. 20 MOhm*cm | |
| 0 .. 20.00 µS/cm | |
| 0 .. 200.00 µS/cm | |
| 0 .. 2.000 mS/cm | |
| 0 .. 20.00 mS/cm | |
| 0 .. 200.00 mS/cm |
input characteristics
| accuracy | 1% of range |
| temperature measuring range | -30 .. +140°C |
| temperature coefficient | adjustable 0,0 .. 8,0 % /°C or non-linear |
output characteristics
| output signal | 3 0/4 .. 20 mA (scaleable, galvanically isolated) | ||||
| load | max. 500 Ohm | ||||
| registration range | Free scaleable within the measuring range | ||||
| serial interface | RS 485 | ||||
|
power supply
| line voltage | 24 / 117 / 230 VAC, +6 / -10 %, 40 .. 60 Hz optional: 24 VDC |
| power consumption | 10 VA |
ambient conditions
| ambient temperature | operation 0 .. +50°C, storage -20 .. +65°C | ||
| relative humidity | max. 90% rH at 40°C (non-condensing) | ||
| protection class |
|
controller
| control response | On/off controller (adjustable hysteresis) P/PI/PID-controller (pulse-pause, pulse-frequency or continous controller output) |
| relays | 3 relays, each with potential-free CO contact, max. 250 V, 6 A, 550 VA |
| onset delay | 0 .. 200 sec till controller active |
| digital input | Controller stop via external contact |
certificates and approvals
| CE-symbol | Declaration of conformity: The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives. The manufacturer confirms successful testing of the product by affixing the CE symbol. |
mechanical construction - wall mounted housing
| material | ABS |
| dimensions | 165x160x85 mm |
| weight | 1.25 kg |
| connection | Spring-loaded terminals |
dialog W 2 CM R
order information
name |
description |
article number |
| dialog W 2CM R | wall mounted housing, 230 VAC | 115140K |
accessories
accessories
| PKV 30-DPS | Converter for PROFIBUS-DP for max. 32 instruments of the K 100 oder dialog series. Converting of RS 485 to PROFIBUS-DP interface, instrument in a housing for installation on a top hat trail, dimension 105 X 105 x 80 mm (HxBxT), connectioncable inclusive |
| S-341 data logger | The bus data logger S-341 on the base of the RS-485 with Kuntze protocol reads, shows, and stores measuring data of up to 10 Kuntze instruments with up to 8 parameters each. |
![]() |
Download datasheetAll information about this product for your reference |
|